Hello, 
I have an EON server installed on which a drive mysteriously went offline a few 
time, so I decided to replace the drive with one I connected to another port. 
Unfortunately the replace operation failed, I think because of hardware issues 
with the replacement drive.  I bought a new replacement drive, but now the pool 
is degraded, and I can't seem to clear the status of the pool in order to 
rebuild with this new device.

The unreliable drive is c2t5d0, the replacement drive was c2t7d0

Here are a few screenshots that will help describe the status of the system.


# cfgadm
Ap_Id                          Type         Receptacle   Occupant     Condition
sata0/0::dsk/c1t0d0            disk         connected    configured   ok
sata0/1::dsk/c1t1d0            disk         connected    configured   ok
sata0/2::dsk/c1t2d0            disk         connected    configured   ok
sata0/3::dsk/c1t3d0            disk         connected    configured   ok
sata0/4::dsk/c1t4d0            disk         connected    configured   ok
sata0/5::dsk/c1t5d0            disk         connected    configured   ok
sata0/6                        sata-port    empty        unconfigured ok
sata0/7                        sata-port    empty        unconfigured ok
sata1/0::dsk/c2t0d0            disk         connected    configured   ok
sata1/1::dsk/c2t1d0            disk         connected    configured   ok
sata1/2::dsk/c2t2d0            disk         connected    configured   ok
sata1/3::dsk/c2t3d0            disk         connected    configured   ok
sata1/4::dsk/c2t4d0            disk         connected    configured   ok
sata1/5::dsk/c2t5d0            disk         connected    configured   ok
sata1/6::dsk/c2t6d0            disk         connected    configured   ok
sata1/7                        disk         connected    unconfigured unknown
usb0/1                         unknown      empty        unconfigured ok
usb0/2                         usb-input    connected    configured   ok
usb0/3                         unknown      empty        unconfigured ok
usb0/4                         unknown      empty        unconfigured ok

# zpool status -v
  pool: tank
 state: DEGRADED
 scrub: resilver completed after 0h0m with 0 errors on Thu Aug 11 04:29:00 2011
config:

        NAME                        STATE     READ WRITE CKSUM
        tank                        DEGRADED     0     0     0
          raidz1-0                  ONLINE       0     0     0
            c1t0d0p0                ONLINE       0     0     0
            c1t1d0p0                ONLINE       0     0     0
            c1t4d0p0                ONLINE       0     0     0
            c1t3d0p0                ONLINE       0     0     0
            c1t2d0p0                ONLINE       0     0     0
            c1t5d0p0                ONLINE       0     0     0
          raidz1-1                  DEGRADED     0     0     0
            c2t0d0                  ONLINE       0     0     0
            c2t1d0                  ONLINE       0     0     0
            c2t2d0                  ONLINE       0     0     0
            replacing-3             DEGRADED     0     0     0
              c2t5d0                ONLINE       0     0     0  9.43M resilvered
              17980209657994758716  UNAVAIL      0     0     0  was 
/dev/dsk/c2t7d0s0
            c2t3d0                  ONLINE       0     0     0
            c2t4d0                  ONLINE       0     0     0
        cache
          c2t6d0                    ONLINE       0     0     0

errors: No known data errors

At this point I'd appreciate suggestions on how to proceed to fix this issue.
-- 
This message posted from opensolaris.org
_______________________________________________
opensolaris-help mailing list
opensolaris-help@opensolaris.org

Reply via email to