On Wed, Apr 4, 2018 at 8:39 AM, Dan Prince <dpri...@redhat.com> wrote:
> Kind of a support question but figured I'd ask here in case there are > suggestions for workarounds for specific machines. > > Setting up a new rack of mixed machines this week and hit this issue > with HP machines using the ipmi power driver for Ironic. Curious if > anyone else has seen this before? The same commands work great with my > Dell boxes! > > ----- > > [root@localhost ~]# cat x.sh > set -x > # this is how Ironic sends its IPMI commands it fails > echo -n password > /tmp/tmprmdOOv > ipmitool -I lanplus -H 172.31.0.19 -U Adminstrator -f /tmp/tmprmdOOv > power status > > # this works great > ipmitool -I lanplus -H 172.31.0.19 -U Administrator -P password power > status > > [root@localhost ~]# bash x.sh > + echo -n password > + ipmitool -I lanplus -H 172.31.0.19 -U Adminstrator -f /tmp/tmprmdOOv > power status > Error: Unable to establish IPMI v2 / RMCP+ session > + ipmitool -I lanplus -H 172.31.0.19 -U Administrator -P password power > status > Chassis Power is on > Very strange. A tcpdump of both would probably be enlightening. :) Also curious what version of ipmitool this is, maybe you're hitting an old bug. // jim