I'm running Juno with ceilometer and trying to produce a new meter which is based on vcpus * F (where F is a constant that is different for each hypervisor).
When I create a VM, I get a new sample for vcpus. However, it does not appear to fire the transformer. The same approach using "cpu" works OK but this one is polling on a regular interval rather than a one off notification when the VM is created. Any suggestions or alternative approaches for how to get a sample based the number of cores scaled by a fixed constant? Tim In my pipeline.yaml sources, - name: vcpu_source interval: 180 meters: - "vcpus" sinks: - hs06_sink In my transformers, I have - name: hs06_sink transformers: - name: "unit_conversion" parameters: target: name: "hs06" unit: "HS06" type: "gauge" scale: "47.0" publishers: - notifier://