Ramon,

It is 
volume_driver=cinder.volume.drivers.dell_emc.sc.storagecenter_iscsi.SCISCSIDriver
 these days.

The volume is mapped to all paths whether they will be used or not.

-----Original Message-----
From: Ramon Orru [mailto:ramon.o...@immobiliare.it] 
Sent: Friday, March 23, 2018 9:07 AM
To: Kanevsky, Arkady <arkady_kanev...@dell.com>; openstack@lists.openstack.org
Subject: Re: [Openstack] iSCSI multipath

Hi Arkady,

is Dell SC driver (connected to a SC9000), to be clear, we have:

volume_driver=cinder.volume.drivers.dell.dell_storagecenter_iscsi.DellStorageCenterISCSIDriver

In our cinder.conf

Ramon


Il 23/03/18 14:52, arkady.kanev...@dell.com ha scritto:
> Ramon,
> Which DellEMC driver is that? VNX?
>
> -----Original Message-----
> From: Ramon Orru [mailto:ramon.o...@immobiliare.it]
> Sent: Friday, March 23, 2018 6:35 AM
> To: openstack@lists.openstack.org
> Subject: [Openstack] iSCSI multipath
>
> Hi everyone,
>
> I'm using delliscsi driver as cinder backend in a new queens cluster.
>
> Checking all nodes connections to storage layer, I figured out that after 
> discovering and logging in (successfully) on every path, all nodes set up 
> only 4 paths on 8 totals.
>
> Multipath on these 4 paths is working well and Im not experiencing any issue, 
> I just wonder why only 4 paths are used... am I ignoring some configuration 
> or default behaviour?
>
> Thanks in advance
>
> Ramon
>
>
> _______________________________________________
> Mailing list: http://lists.openstack.org/cgi-bin/mailman/listinfo/openstack
> Post to     : openstack@lists.openstack.org
> Unsubscribe : http://lists.openstack.org/cgi-bin/mailman/listinfo/openstack

_______________________________________________
Mailing list: http://lists.openstack.org/cgi-bin/mailman/listinfo/openstack
Post to     : openstack@lists.openstack.org
Unsubscribe : http://lists.openstack.org/cgi-bin/mailman/listinfo/openstack

Reply via email to