On Wed, May 10, 2017 at 3:59 PM, Bartlomiej Zolnierkiewicz
<b.zolnier...@samsung.com> wrote:
> On Monday, May 08, 2017 10:26:49 PM Linus Walleij wrote:
>> On Mon, May 8, 2017 at 12:47 PM, Bartlomiej Zolnierkiewicz
>> <b.zolnier...@samsung.com> wrote:

>> So depending on whether they use an FPGA or an ASIC the values are
>> different, no matter what frequency (50 or 66 MHz) is used. So it is not
>> derived from frequency.
>>
>> So I think it makes most sense to have it in the device tree as we don't
>> know what designs are out there.
>
> I still would prefer to keep timing values private to the driver and just
> select the controller type (FPGA/ASIC) using the device tree.

OK I'll revert to static timings in the driver, no problem.

Yours,
Linus Walleij
_______________________________________________
openwrt-devel mailing list
openwrt-devel@lists.openwrt.org
https://lists.openwrt.org/cgi-bin/mailman/listinfo/openwrt-devel