Hi Binghan,

Please see section 6 of [0] for HW requirements and
limitations of latency measurement in MoonGen (typically
only a sub-set of packets can be measured for latency).
IMO, this is a small compromise when considering an
opensource solution for the test device.

regards,
Al

[0] 
https://www.researchgate.net/publication/266913386_MoonGen_A_Scriptable_High-Speed_Packet_Generator


From: opnfv-tech-discuss-boun...@lists.opnfv.org 
[mailto:opnfv-tech-discuss-boun...@lists.opnfv.org] On Behalf Of Bill 
Michalowski
Sent: Wednesday, August 31, 2016 8:34 AM
To: Christian Trautman
Cc: Binghan; opnfv-tech-discuss@lists.opnfv.org
Subject: Re: [opnfv-tech-discuss] [VSPERF] How to enable latency test?

Thanks Christian!  I just assigned this to myself and will integrate the 
feature into VSPERF in the near future.
- Bill
----- Original Message -----
From: Christian Trautman <ctrau...@redhat.com<mailto:ctrau...@redhat.com>>
To: Binghan <binghan...@gmail.com<mailto:binghan...@gmail.com>>
Cc: 
opnfv-tech-discuss@lists.opnfv.org<mailto:opnfv-tech-discuss@lists.opnfv.org>
Sent: Tue, 30 Aug 2016 22:19:49 -0400 (EDT)
Subject: Re: [opnfv-tech-discuss] [VSPERF] How to enable latency test?
Hi Binghan,
Moongen does support collection of latency stats so it just needs to be added 
to VSPerf. We will add this as a JIRA ticket and advise you when its available.
Thanks.
-Christian,
________________________________
From: "Christian Trautman" <ctrau...@redhat.com<mailto:ctrau...@redhat.com>>
To: "Binghan" <binghan...@gmail.com<mailto:binghan...@gmail.com>>
Cc: 
opnfv-tech-discuss@lists.opnfv.org<mailto:opnfv-tech-discuss@lists.opnfv.org>
Sent: Tuesday, August 30, 2016 9:14:40 PM
Subject: Re: [opnfv-tech-discuss] [VSPERF] How to enable latency test?
Hi Binghan,
Moongen in VSPerf does not currently collect latency stats. I will inquire with 
the developers if this is planned in the near future and get back to you.
-Christian,
________________________________
From: "Binghan" <binghan...@gmail.com<mailto:binghan...@gmail.com>>
To: "MartinX Klozik" <martinx.klo...@intel.com<mailto:martinx.klo...@intel.com>>
Cc: 
opnfv-tech-discuss@lists.opnfv.org<mailto:opnfv-tech-discuss@lists.opnfv.org>
Sent: Tuesday, August 30, 2016 11:04:15 AM
Subject: Re: [opnfv-tech-discuss] [VSPERF] How to enable latency test?
Hi Martin,
I am using Moongen, I cannot find latency result from Moongen log, I consider 
that VSperf parse Moongen log to get the test result.
And about the configuration, I did not use the custom.conf, everything is by 
default. Sure, traffic generator part has been reconfigured, but nothing else.
I attached pvp test log file and test report.
Thanks a lot.

BRs,
Binghan

On Tue, Aug 30, 2016 at 4:19 PM, Klozik, MartinX 
<martinx.klo...@intel.com<mailto:martinx.klo...@intel.com>> wrote:
Hi Binghan,

Could you please sent us following info?
* what traffic generator you use
* your vsperf configuration
* full test output

In general these values are reported by traffic generator and the level of 
implementation might be different among supported traffic
generators. It would be good to check if these latencies are visible in traffic 
generator itself.

Thank you,
Martin

From:opnfv-tech-discuss-boun...@lists.opnfv.org<mailto:opnfv-tech-discuss-boun...@lists.opnfv.org>
 
[mailto:opnfv-tech-discuss-boun...@lists.opnfv.org<mailto:opnfv-tech-discuss-boun...@lists.opnfv.org>]
On Behalf Of Binghan
Sent: Tuesday, August 30, 2016 3:02 PM
To:opnfv-tech-discuss@lists.opnfv.org<mailto:opnfv-tech-discuss@lists.opnfv.org>
Subject: [opnfv-tech-discuss] [VSPERF] How to enable latency test?

Hi VSPERF experts,

I am trying to use VSPERF to benchmark OVS performance.

I use default configuration, but no matter I run PVP test or P2P test, the 
latency result is always 0. Do I need to configure anything special to enable 
latency test?

BRs,
Binghan

[INFO ]  2016-08-26 22:00:15,727 : (root) -          Key: throughput_rx_fps, 
Value: 19123026.000000
[INFO ]  2016-08-26 22:00:15,727 : (root) -          Key: throughput_rx_mbps, 
Value: 9950.989
[INFO ]  2016-08-26 22:00:15,727 : (root) -          Key: 
throughput_rx_percent, Value: 64.253
[INFO ]  2016-08-26 22:00:15,727 : (root) -          Key: tx_rate_fps, Value: 
19123026.000000
[INFO ]  2016-08-26 22:00:15,727 : (root) -          Key: tx_rate_mbps, Value: 
12850.673
[INFO ]  2016-08-26 22:00:15,728 : (root) -          Key: tx_rate_percent, 
Value: 64.253
[INFO ]  2016-08-26 22:00:15,728 : (root) -          Key: min_latency_ns, 
Value: 0.000
[INFO ]  2016-08-26 22:00:15,728 : (root) -          Key: max_latency_ns, 
Value: 0.000
[INFO ]  2016-08-26 22:00:15,728 : (root) -          Key: avg_latency_ns, 
Value: 0.000
[INFO ]  2016-08-26 22:00:15,728 : (root) -          Key: type, Value: rfc2544
[INFO ]  2016-08-26 22:00:15,728 : (root) -          Key: packet_size, Value: 64

--------------------------------------------------------------

Intel Research and Development Ireland Limited

Registered in Ireland

Registered Office: Collinstown Industrial Park, Leixlip, County Kildare

Registered Number: 308263

This e-mail and any attachments may contain confidential material for the
sole use of the intended recipient(s). Any review or distribution by others is
strictly prohibited. If you are not the intended recipient, please contact the
sender and delete all copies.

_______________________________________________
opnfv-tech-discuss mailing list
opnfv-tech-discuss@lists.opnfv.org<mailto:opnfv-tech-discuss@lists.opnfv.org>
https://lists.opnfv.org/mailman/listinfo/opnfv-tech-discuss

_______________________________________________
opnfv-tech-discuss mailing list
opnfv-tech-discuss@lists.opnfv.org<mailto:opnfv-tech-discuss@lists.opnfv.org>
https://lists.opnfv.org/mailman/listinfo/opnfv-tech-discuss
_______________________________________________
opnfv-tech-discuss mailing list
opnfv-tech-discuss@lists.opnfv.org
https://lists.opnfv.org/mailman/listinfo/opnfv-tech-discuss

Reply via email to