On 7 May 2009, at 20:52, Andrew Hall wrote:

>> The slave server doesn’t really have a way to know that the reverse  
>> tunnel is down...
>
> This is what confuses me. The autossh process is running on the slave
> but the tunnel from master to slave is no longer running. Shouldn't
> autossh (by definition?) be picking up on this?


True.

The option to autossh in rc.opsview-slave disables the monitoring port  
(-M 0). The documentation (http://www.harding.motd.ca/autossh/README)  
suggests using openssh's ServerAliveCountMax and ServerAliveInterval  
options instead, which we do.

Can you like try with the -M set to a specific port number?

Ton
_______________________________________________
Opsview-users mailing list
[email protected]
http://lists.opsview.org/listinfo/opsview-users