Hello!

Tried to add a comment to the opsview blog, but it doesn't accept my
text (special chars?), so I blogged it and share this with the list:

Ton explained¹ how to modify NRPE for large output. But if you use a
distributed environment with master and slave nodes the large NRPE
output has to be forwarded to to the master using NSCA which limites the
plugin output to 512B. So you have to patch and recompile NSCA to get
your big 16k-NRPE ouput displayed and processed by the master.

The patch i created is available at my blog:
http://henry78.at/2009/10/opsview-and-large-check-results-patch-nsca/

Feel free to use and comment it!

-- 
regards, Henry

¹ http://opsview-blog.opsera.com/dotorg/2008/08/enhancing-nrpe.html