On Tue, May 02, 2017 at 01:22:35PM -0700, Han Zhou wrote: > Normally the OVS JSON-RPC library does not probe idle connections across > Unix domain sockets, since the kernel can tell OVS whether the connections > are truly connected without probes, but ovn-controller carelessly > overrode that. > > (This should not be an issue in typical OVN deployments, because the OVN SB > database is normally accessed via TCP or SSL.) > > CC: Nirapada Ghosh <[email protected]> > Fixes: 715038b6b222 ("ovn-controller: reload configured SB probe timer") > Signed-off-by: Han Zhou <[email protected]> > Co-authored-by: Ben Pfaff <[email protected]>
Thanks! I applied this to master. _______________________________________________ dev mailing list [email protected] https://mail.openvswitch.org/mailman/listinfo/ovs-dev