On Tue, May 02, 2017 at 01:22:35PM -0700, Han Zhou wrote:
> Normally the OVS JSON-RPC library does not probe idle connections across
> Unix domain sockets, since the kernel can tell OVS whether the connections
> are truly connected without probes, but ovn-controller carelessly
> overrode that.
> 
> (This should not be an issue in typical OVN deployments, because the OVN SB
> database is normally accessed via TCP or SSL.)
> 
> CC: Nirapada Ghosh <[email protected]>
> Fixes: 715038b6b222 ("ovn-controller: reload configured SB probe timer")
> Signed-off-by: Han Zhou <[email protected]>
> Co-authored-by: Ben Pfaff <[email protected]>

Thanks!  I applied this to master.