On Tue, May 02, 2017 at 01:22:35PM -0700, Han Zhou wrote:
> Normally the OVS JSON-RPC library does not probe idle connections across
> Unix domain sockets, since the kernel can tell OVS whether the connections
> are truly connected without probes, but ovn-controller carelessly
> overrode that.
> 
> (This should not be an issue in typical OVN deployments, because the OVN SB
> database is normally accessed via TCP or SSL.)
> 
> CC: Nirapada Ghosh <ngh...@us.ibm.com>
> Fixes: 715038b6b222 ("ovn-controller: reload configured SB probe timer")
> Signed-off-by: Han Zhou <zhou...@gmail.com>
> Co-authored-by: Ben Pfaff <b...@ovn.org>

Thanks!  I applied this to master.
_______________________________________________
dev mailing list
d...@openvswitch.org
https://mail.openvswitch.org/mailman/listinfo/ovs-dev

Reply via email to