On 20 Jun 2019, at 4:15, William Tu wrote:
>> The PVP test seems to work fine however after a while it stops >> forwarding: >> >> $ ovs-ofctl dump-flows ovs_pvp_br0 >> cookie=0x0, duration=8.510s, table=0, n_packets=1, n_bytes=1020, >> in_port=eno1 actions=output:tapVM >> cookie=0x0, duration=8.504s, table=0, n_packets=1, n_bytes=252, >> in_port=tapVM actions=output:eno1 >> >> Results: >> >> "Physical port, ""eno1"", speed 10 Gbit/s, traffic rate 100%" >> "Physical to Virtual to Physical test, L3 flows[port redirect]" >> ,Packet size >> Number of flows,64,256,1024 >> 10,13448,131687,0 >> 100,596,0,0 >> 1000,596,0,0 >> > > Hi Eelco, > > What traffic generator are you using? > Maybe I can try to reproduce it on my testbed. I’m using a Xena tester, with the following PVP script: https://github.com/chaudron/ovs_perf The config I use is: ~/ovs_perf/ovs_performance.py -d -l testrun_log.txt \ --tester-type=xena --tester-address 10.19.188.64 --tester-interface 6,1 \ --ovs-address $DUT \ --ovs-user root --ovs-password $DUT_PW \ --dut-vm-address 192.168.122.164 \ --dut-vm-user root --dut-vm-password root \ --virtual-interface tapVM \ --dut-vm-nic-pci=0000:00:02.0 \ --dut-vm-nic-queues=1 \ --physical-interface eno1 \ --physical-speed=10 \ --stream-list=10,100,1000 \ --packet-list=64,256,1024 \ --warm-up --warm-up-no-fail --warm-up-time=5 \ --skip-pv-test \ --flow-rule-type=port \ --testpmd-startup-delay=8 \ --no-bridge-config _______________________________________________ dev mailing list d...@openvswitch.org https://mail.openvswitch.org/mailman/listinfo/ovs-dev