We have observed meters working unexpected if traffic is 3+Gbit/s with multiple connections.
now_ms is not pretected by meter->lock, we may get a negative long_delta_ms when another cpu updated meter->used, then: delta_ms = (u32)long_delta_ms; which will be a large value. band->bucket += delta_ms * band->rate; then we get a wrong band->bucket. Fixes: 96fbc13d7e77 ("openvswitch: Add meter infrastructure") Signed-off-by: Tao Liu <thomas....@ucloud.cn> --- net/openvswitch/meter.c | 3 ++- 1 file changed, 2 insertions(+), 1 deletion(-) diff --git a/net/openvswitch/meter.c b/net/openvswitch/meter.c index 96b524c..c50ab7f 100644 --- a/net/openvswitch/meter.c +++ b/net/openvswitch/meter.c @@ -593,7 +593,7 @@ static int ovs_meter_cmd_del(struct sk_buff *skb, struct genl_info *info) bool ovs_meter_execute(struct datapath *dp, struct sk_buff *skb, struct sw_flow_key *key, u32 meter_id) { - long long int now_ms = div_u64(ktime_get_ns(), 1000 * 1000); + long long int now_ms; long long int long_delta_ms; struct dp_meter_band *band; struct dp_meter *meter; @@ -610,6 +610,7 @@ bool ovs_meter_execute(struct datapath *dp, struct sk_buff *skb, /* Lock the meter while using it. */ spin_lock(&meter->lock); + now_ms = div_u64(ktime_get_ns(), 1000 * 1000); long_delta_ms = (now_ms - meter->used); /* ms */ /* Make sure delta_ms will not be too large, so that bucket will not -- 1.8.3.1 _______________________________________________ dev mailing list d...@openvswitch.org https://mail.openvswitch.org/mailman/listinfo/ovs-dev