Acked-by: Mark Michelson <mmich...@redhat.com>

On 7/6/21 10:41 AM, Dumitru Ceara wrote:
Also, shorten the CONTROLLER_LOOP_STOPWATCH_NAME name as there is a bug
in lib/stopwatch.c which fails to report an error when the stopwatch
name is longer than 32 characters.  CONTROLLER_LOOP_STOPWATCH_NAME was
getting very close to that and future commits might mimic the long name
and happen to go over the limit.

Signed-off-by: Dumitru Ceara <dce...@redhat.com>
---
Note: The OVS lib/stopwatch.c implementation should also be fixed to
report an error (or even assert) if the name supplied to
stopwatch_create() is longer than 32 characters.  But that's out of the
scope of this patch.
---
  controller/ovn-controller.c | 7 ++++++-
  1 file changed, 6 insertions(+), 1 deletion(-)

diff --git a/controller/ovn-controller.c b/controller/ovn-controller.c
index 9050380f3..6a9c25f28 100644
--- a/controller/ovn-controller.c
+++ b/controller/ovn-controller.c
@@ -93,7 +93,8 @@ static unixctl_cb_func debug_delay_nb_cfg_report;
  #define DEFAULT_PROBE_INTERVAL_MSEC 5000
  #define OFCTRL_DEFAULT_PROBE_INTERVAL_SEC 0
-#define CONTROLLER_LOOP_STOPWATCH_NAME "ovn-controller-flow-generation"
+#define CONTROLLER_LOOP_STOPWATCH_NAME "flow-generation"
+#define OFCTRL_PUT_STOPWATCH_NAME "flow-installation"
#define OVS_NB_CFG_NAME "ovn-nb-cfg" @@ -2845,6 +2846,7 @@ main(int argc, char *argv[])
      update_sb_monitors(ovnsb_idl_loop.idl, NULL, NULL, NULL, false);
stopwatch_create(CONTROLLER_LOOP_STOPWATCH_NAME, SW_MS);
+    stopwatch_create(OFCTRL_PUT_STOPWATCH_NAME, SW_MS);
/* Define inc-proc-engine nodes. */
      ENGINE_NODE_CUSTOM_DATA(ct_zones, "ct_zones");
@@ -3292,6 +3294,8 @@ main(int argc, char *argv[])
                      pflow_output_data = engine_get_data(&en_pflow_output);
                      if (lflow_output_data && pflow_output_data &&
                          ct_zones_data) {
+                        stopwatch_start(OFCTRL_PUT_STOPWATCH_NAME,
+                                        time_msec());
                          ofctrl_put(&lflow_output_data->flow_table,
                                     &pflow_output_data->flow_table,
                                     &ct_zones_data->pending,
@@ -3299,6 +3303,7 @@ main(int argc, char *argv[])
                                     ofctrl_seqno_get_req_cfg(),
                                     engine_node_changed(&en_lflow_output),
                                     engine_node_changed(&en_pflow_output));
+                        stopwatch_stop(OFCTRL_PUT_STOPWATCH_NAME, time_msec());
                      }
                      ofctrl_seqno_run(ofctrl_get_cur_cfg());
                      if_status_mgr_run(if_mgr, binding_data, !ovnsb_idl_txn,


_______________________________________________
dev mailing list
d...@openvswitch.org
https://mail.openvswitch.org/mailman/listinfo/ovs-dev

Reply via email to