On Fri, Feb 10, 2023 at 05:03:13PM +0100, Adrián Moreno wrote:
> From: Adrian Moreno <amore...@redhat.com>
> 
> IPFIX templates have to be sent for each Observation Domain ID.
> Currently, a timer is kept at each dpif_ipfix_exporter to send them.
> This works fine for per-bridge sampling where there is only one
> Observation Domain ID per exporter. However, this is does not work for
> per-flow sampling where more than one Observation Domain IDs can be
> specified by the controller. In this case, ovs-vswitchd will only send
> template information for one (arbitrary) DomainID.
> 
> Fix per-flow sampling by using an hmap to keep a timer for each
> Observation Domain ID.
> 
> Signed-off-by: Adrian Moreno <amore...@redhat.com>

Reviewed-by: Simon Horman <simon.hor...@corigine.com>