The offload thread calling ufid_to_rte_flow_disassociate() may be the
last one holding a reference on the netdev and physdev.
So displaying informations about them might trigger a crash when
removing a physical port.
Fixes: faf71e492263 ("netdev-dpdk: Print port name in offload API messages.")
Signed-off-by: David Marchand <[email protected]>
---
lib/netdev-offload-dpdk.c | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)
diff --git a/lib/netdev-offload-dpdk.c b/lib/netdev-offload-dpdk.c
index 7c91f8a799..14bc877719 100644
--- a/lib/netdev-offload-dpdk.c
+++ b/lib/netdev-offload-dpdk.c
@@ -2345,13 +2345,13 @@ netdev_offload_dpdk_flow_destroy(struct
ufid_to_rte_flow_data *rte_flow_data)
ovsrcu_get(void *, &netdev->hw_info.offload_data);
data->rte_flow_counters[tid]--;
- ufid_to_rte_flow_disassociate(rte_flow_data);
VLOG_DBG_RL(&rl, "%s/%s: rte_flow 0x%"PRIxPTR
" flow destroy %d ufid " UUID_FMT,
netdev_get_name(netdev), netdev_get_name(physdev),
(intptr_t) rte_flow,
netdev_dpdk_get_port_id(physdev),
UUID_ARGS((struct uuid *) ufid));
+ ufid_to_rte_flow_disassociate(rte_flow_data);
} else {
VLOG_ERR("Failed flow: %s/%s: flow destroy %d ufid " UUID_FMT,
netdev_get_name(netdev), netdev_get_name(physdev),
--
2.40.1