From: Lucas Alvares Gomes <lucasago...@gmail.com> In order for the CMS to know which Chassis a distributed gateway port is bond to, this patch updates the ovn-northd daemon to populate the Logical_Router_Port table with that information.
To avoid changing the database schema, ovn-northd is setting a new key called "hosting-chassis" in the options column from the LRP table. This key value points to the name of the Chassis that is currently hosting the distributed port. Reported-at: https://bugzilla.redhat.com/show_bug.cgi?id=2107515 Signed-off-by: Lucas Alvares Gomes <lucasago...@gmail.com> --- v3 -> v4 * Removed smap_clone for updating the options and replaced it with smap_replace/smap_remove * Updated the test to also assert the removal of the hosting-chassis key by northd v2 -> v3 * Fixed memory leak * Separate the logic to update the router port into their own function * Use attribute l3dgw_port to find the GW port v1 -> v2 * Rebased on the main branch * Updated the ovnsb_db_run() and handle_port_binding_changes() functions to include the LR ports as a parameter northd/en-sync-from-sb.c | 2 +- northd/northd.c | 30 +++++++++++++++++++++++++-- northd/northd.h | 3 ++- ovn-nb.xml | 15 ++++++++++++++ tests/ovn-northd.at | 44 ++++++++++++++++++++++++++++++++++++++++ 5 files changed, 90 insertions(+), 4 deletions(-) diff --git a/northd/en-sync-from-sb.c b/northd/en-sync-from-sb.c index 55ece2d16..4109aebe4 100644 --- a/northd/en-sync-from-sb.c +++ b/northd/en-sync-from-sb.c @@ -60,7 +60,7 @@ en_sync_from_sb_run(struct engine_node *node, void *data OVS_UNUSED) stopwatch_start(OVNSB_DB_RUN_STOPWATCH_NAME, time_msec()); ovnsb_db_run(eng_ctx->ovnnb_idl_txn, eng_ctx->ovnsb_idl_txn, sb_pb_table, sb_ha_ch_grp_table, sb_ha_ch_grp_by_name, - &nd->ls_ports); + &nd->ls_ports, &nd->lr_ports); stopwatch_stop(OVNSB_DB_RUN_STOPWATCH_NAME, time_msec()); } diff --git a/northd/northd.c b/northd/northd.c index b9605862e..c6752884c 100644 --- a/northd/northd.c +++ b/northd/northd.c @@ -17780,6 +17780,22 @@ build_ha_chassis_group_ref_chassis(struct ovsdb_idl_index *ha_ch_grp_by_name, } } +/* Set the "hosting-chassis" option in the NBDB logical_router_port + * table indicating which chassis the distributed port is bond to. */ +static void +handle_cr_port_binding_changes(const struct sbrec_port_binding *sb, + struct ovn_port *orp) +{ + if (sb->chassis) { + nbrec_logical_router_port_update_options_setkey( + orp->l3dgw_port->nbrp, "hosting-chassis", + sb->chassis->name); + } else { + nbrec_logical_router_port_update_options_delkey( + orp->l3dgw_port->nbrp, "hosting-chassis"); + } +} + /* Handle changes to the 'chassis' column of the 'Port_Binding' table. When * this column is not empty, it means we need to set the corresponding logical * port as 'up' in the northbound DB. */ @@ -17789,6 +17805,7 @@ handle_port_binding_changes(struct ovsdb_idl_txn *ovnsb_txn, const struct sbrec_ha_chassis_group_table *sb_ha_ch_grp_table, struct ovsdb_idl_index *sb_ha_ch_grp_by_name, struct hmap *ls_ports, + struct hmap *lr_ports, struct shash *ha_ref_chassis_map) { const struct sbrec_port_binding *sb; @@ -17807,6 +17824,14 @@ handle_port_binding_changes(struct ovsdb_idl_txn *ovnsb_txn, } SBREC_PORT_BINDING_TABLE_FOR_EACH (sb, sb_pb_table) { + + struct ovn_port *orp = ovn_port_find(lr_ports, sb->logical_port); + + if (orp && is_cr_port(orp)) { + handle_cr_port_binding_changes(sb, orp); + continue; + } + struct ovn_port *op = ovn_port_find(ls_ports, sb->logical_port); if (!op || !op->nbsp) { @@ -17855,7 +17880,8 @@ ovnsb_db_run(struct ovsdb_idl_txn *ovnnb_txn, const struct sbrec_port_binding_table *sb_pb_table, const struct sbrec_ha_chassis_group_table *sb_ha_ch_grp_table, struct ovsdb_idl_index *sb_ha_ch_grp_by_name, - struct hmap *ls_ports) + struct hmap *ls_ports, + struct hmap *lr_ports) { if (!ovnnb_txn || !ovsdb_idl_has_ever_connected(ovsdb_idl_txn_get_idl(ovnsb_txn))) { @@ -17864,7 +17890,7 @@ ovnsb_db_run(struct ovsdb_idl_txn *ovnnb_txn, struct shash ha_ref_chassis_map = SHASH_INITIALIZER(&ha_ref_chassis_map); handle_port_binding_changes(ovnsb_txn, sb_pb_table, sb_ha_ch_grp_table, - sb_ha_ch_grp_by_name, ls_ports, + sb_ha_ch_grp_by_name, ls_ports, lr_ports, &ha_ref_chassis_map); if (ovnsb_txn) { update_sb_ha_group_ref_chassis(sb_ha_ch_grp_table, diff --git a/northd/northd.h b/northd/northd.h index f3e63b1e1..44dc11009 100644 --- a/northd/northd.h +++ b/northd/northd.h @@ -326,7 +326,8 @@ void ovnsb_db_run(struct ovsdb_idl_txn *ovnnb_txn, const struct sbrec_port_binding_table *, const struct sbrec_ha_chassis_group_table *, struct ovsdb_idl_index *sb_ha_ch_grp_by_name, - struct hmap *ls_ports); + struct hmap *ls_ports, + struct hmap *lr_ports); bool northd_handle_ls_changes(struct ovsdb_idl_txn *, const struct northd_input *, struct northd_data *); diff --git a/ovn-nb.xml b/ovn-nb.xml index 4fbf4f7e5..b1e9ba724 100644 --- a/ovn-nb.xml +++ b/ovn-nb.xml @@ -3113,6 +3113,21 @@ or port on the logical router. It is otherwise ignored. </p> </column> + + <column name="options" key="hosting-chassis"> + <p> + This option is populated by <code>ovn-northd</code>, rather + than by the CMS plugin. + </p> + + <p> + When a distributed gateway port is bound to a location in + the OVN Southbound database + <ref db="OVN_Southbound" table="Port_Binding"/> + <code>ovn-northd</code> will populate this option with the + name of the Chassis that is currently hosting this port. + </p> + </column> </group> </group> diff --git a/tests/ovn-northd.at b/tests/ovn-northd.at index 3e06f14c9..ad398da0c 100644 --- a/tests/ovn-northd.at +++ b/tests/ovn-northd.at @@ -169,6 +169,50 @@ AT_CHECK([test x`ovn-nbctl lsp-get-up S1-R1` = xup]) AT_CLEANUP ]) +OVN_FOR_EACH_NORTHD_NO_HV([ +AT_SETUP([check Logical Router Port hosting-chassis option]) +ovn_start + +check ovn-sbctl chassis-add ch1 geneve 127.0.0.2 + +check ovn-nbctl lr-add lr1 +check ovn-nbctl lrp-add lr1 lrp1 00:00:00:00:00:01 10.0.0.1/24 +check ovn-nbctl ls-add ls1 +check ovn-nbctl lsp-add ls1 lsp1 -- \ + lsp-set-addresses lsp1 router -- \ + lsp-set-type lsp1 router -- \ + lsp-set-options lsp1 router-port=lrp1 + +# Make lrp a cr-port +check ovn-nbctl lrp-set-gateway-chassis lrp1 ch1 + +ovn-nbctl --wait=sb sync + +wait_row_count Port_Binding 1 logical_port=cr-lrp1 \ + options:always-redirect="true" options:distributed-port="lrp1" + +# Simulate cr-port being bound to ch1 +ch1_uuid=`ovn-sbctl --bare --columns _uuid find Chassis name="ch1"` +ovn-sbctl set Port_Binding cr-lrp1 chassis=${ch1_uuid} + +ovn-nbctl --wait=sb sync + +# Check for the hosting-chassis option being set by northd +wait_row_count nb:Logical_Router_Port 1 name=lrp1 options:hosting-chassis=ch1 + +# Now remove the chassis from the port binding record and assert that the +# hosting-chassis option was removed by northd +ovn-sbctl clear Port_Binding cr-lrp1 chassis + +sleep 1 + +AT_CHECK([ovn-sbctl get Port_Binding cr-lrp1 options:hosting-chassis], +[1], [], [ovn-sbctl: no key "hosting-chassis" in Port_Binding record "cr-lrp1" column options +]) + +AT_CLEANUP +]) + OVN_FOR_EACH_NORTHD_NO_HV([ AT_SETUP([check LRP external id propagation to SBDB]) ovn_start -- 2.41.0 _______________________________________________ dev mailing list d...@openvswitch.org https://mail.openvswitch.org/mailman/listinfo/ovs-dev