In the OVS documentation quoted below, it states that "physical ingress ports 
(which need not be part of any switch)...".

Is it correct to assume that the physical ingress port (of the gre tunnel) can 
optionally be part of the switch that also has the gre tunnel?  If so, is there 
documented example configuration?  (So far, I've only seen OVS configuration 
where switch consists of only gre tunnel but not the physical ingress port of 
the tunnel.)

Thanks,
Helen

    -----Original Message-----
    From: Ben Pfaff <b...@ovn.org> 
    Sent: Friday, July 2, 2021 1:46 PM
    To: Dr. Shukri George Abdallah <sabdal...@mitre.org>
    Cc: ovs-discuss@openvswitch.org
    Subject: Re: [EXT] Re: [ovs-discuss] How to match on the physical and 
logical ingress ports

    The documentation says this:

           A  packet’s  ingress  port and physical ingress port are identical 
except
           for packets processed by a switch feature such as  bonding  or  
tunneling
           that  makes  a  packet  appear to arrive on a ``virtual’’ port 
associated
           with the bond or the tunnel. For such packets, the ingress  port  is 
 the
           virtual  port  and  the physical ingress port is, naturally, the 
physical
           port. Open vSwitch implements both bonding and tunneling, but its 
bonding
           implementation  does  not use virtual ports and its tunnels are 
typically
           not on the same OpenFlow switch as their physical  ingress  ports  
(which
           need not be part of any switch), so the ingress port and physical 
ingress
           port are always the same in Open vSwitch.

    For bonding, OVS in_port always matches on the physical input port.

    For tunneling, OVS doesn't pass along the physical input port but only the 
virtual one.  You might be able to set the packet mark in the physical bridge 
and then match on it in the virtual one, though.

    On Thu, Jul 01, 2021 at 06:04:29PM +0000, Dr. Shukri George Abdallah wrote:
    > Hi
    > 
    > Please see 
https://opennetworking.org/wp-content/uploads/2014/10/openflow-switch-v1.3.5.pdf
 Section 7.2.3.9 .This link uses the term "logical"
    > 
    > Please see https://www.man7.org/linux/man-pages/man7/ovs-fields.7.html. 
This link uses the term "virtual".
    > 
    > The context is GRE tunneling
    > 
    > Shukri
    > -----Original Message-----
    > From: Ben Pfaff <b...@ovn.org>
    > Sent: Thursday, July 1, 2021 1:37 PM
    > To: Dr. Shukri George Abdallah <sabdal...@mitre.org>
    > Cc: ovs-discuss@openvswitch.org
    > Subject: [EXT] Re: [ovs-discuss] How to match on the physical and 
    > logical ingress ports
    > 
    > On Thu, Jul 01, 2021 at 02:51:13PM +0000, Dr. Shukri George Abdallah 
wrote:
    > > When the physical ingress port is different than the logical ingress 
    > > port, using the ovs-ofctl utility, how can one match on the physical 
    > > and logical ingress ports?
    > 
    > How are you defining "physical" and "logical" ingress ports here?  Out of 
context, it's not clear.