Hello,

I know that now is too late for 'idea' correction, but in 'real' electronic world all 'switches' like DSxxxx with open drain/collector and second pin grounded, have clearly defined conducted state as 0 because this IS a 0 state in CMOS and TTL logic. I saw on the list also some problems related to this strange assumption (for eg. thread about DS2413). In DS2405 this is reasonable because Dallas really made io pin with inverter and started 'inverting things', but in DS2413 or DS2408 it isn't. Maybe this issue should be better documented? Some warnings to electronic guys? :-)
Despite of this - good work!


Regards

majek
--
"If you want something done...do yourself!"
Jean-Baptiste Emmanuel Zorg


-------------------------------------------------------
This SF.Net email is sponsored by the JBoss Inc.
Get Certified Today * Register for a JBoss Training Course
Free Certification Exam for All Training Attendees Through End of 2005
Visit http://www.jboss.com/services/certification for more information
_______________________________________________
Owfs-developers mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/owfs-developers

Reply via email to