Looks pretty good. CRC16 and bus-echo are both triggered by error bits in 1-wire communication. Since communication errors are retried 3 times, it looks like the bus traffic is eventually working. Probably the best way to use this data is to see if changes in network wiring increase your error rate.
Paul Alfille
On 11/7/06, Rob Conway <[EMAIL PROTECTED]> wrote:
Its run for 12 hours with the following
errors. I would assume there will always be some errors on any data
communications bus...are these acceptable for 12 hours operation ?
bus.0/statistics/errors
statistics/errors
No errors reported
-------------------------------------------------------------------------