Ben Griffith wrote: > I just tried it by adding an unpowered sensor to my net and doing the > following... > > echo 1 > simultaneous/temperature > cat 10.*/temperature > > The result was that it paused to do the conversion on the one unpowered > sensor, and all the powered ones came up right away. The unpowered > sensor probably tries to do the conversion with all the powered ones, > but since the data bus isn't being held high the conversion fails. > >
The first guy will delay, then the others come up quickly after that. I think the sensors are smart enough to know they are on parasitic power and ignore the simultaneous command. Out of curiosity, are you getting more the 5 answers a second when running simultaneous not from cache? If so, I will need to look into my setup a bit more. jerry ------------------------------------------------------------------------- Take Surveys. Earn Cash. Influence the Future of IT Join SourceForge.net's Techsay panel and you'll get the chance to share your opinions on IT & business topics through brief surveys - and earn cash http://www.techsay.com/default.php?page=join.php&p=sourceforge&CID=DEVDEV _______________________________________________ Owfs-developers mailing list Owfs-developers@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/owfs-developers