Ben Griffith wrote:
> I just tried it by adding an unpowered sensor to my net and doing the 
> following...
> 
> echo 1 > simultaneous/temperature
> cat 10.*/temperature
> 
> The result was that it paused to do the conversion on the one unpowered 
> sensor, and all the powered ones came up right away.  The unpowered 
> sensor probably tries to do the conversion with all the powered ones, 
> but since the data bus isn't being held high the conversion fails.
> 
> 

The first guy will delay, then the others come up quickly after that. I 
think the sensors are smart enough to know they are on parasitic power 
and ignore the simultaneous command.

Out of curiosity, are you getting more the 5 answers a second when 
running simultaneous not from cache? If so, I will need to look into my 
setup a bit more.

jerry

-------------------------------------------------------------------------