Am Freitag, 9. September 2011, 02:00:28 schrieb p4trykx: > > But this is a quote form datasheet. Page 5 table with pin description > http://datasheets.maxim-ic.com/en/ds/DS2408.pdf > > ...When configured as STRB, an output strobe will occur after a PIO write > (see Channel-Access Write command) > or after a PIO Read (see Channel-Access Read command). The power-on > default function of this pin is RST. > Sorry, I misunderstood you, because you talked about the "rstz" function of the pin, not the strobe function.
There is no strobe when using the "sensed" node because it isn't using the "Channel Access Read" command but accessing the register file directly. Kind regards Jan ------------------------------------------------------------------------------ Why Cloud-Based Security and Archiving Make Sense Osterman Research conducted this study that outlines how and why cloud computing security and archiving is rapidly being adopted across the IT space for its ease of implementation, lower cost, and increased reliability. Learn more. http://www.accelacomm.com/jaw/sfnl/114/51425301/ _______________________________________________ Owfs-developers mailing list Owfs-developers@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/owfs-developers