Hello,
I'm running owhttpd vesion 2.8p14. There is a bug, so it is not possible to
set negative alarm values for DS18B20 sensors.
$wget -qO - --no-proxy
http://owhttpd.host/json/28.1E9257030000/templow?templow=5
templow 5
ok, no problem!
$wget -qO - --no-proxy
http://owhttpd.host/json/28.1E9257030000/templow?templow=-5
templow 0
BUG!
$wget -qO - --no-proxy
http://owhttpd.host/json/28.1E9257030000/templow?templow=251
templow -5
That is what I really need, but setting in some unexpected way. I have
checked, it works, alarming if temperature is below -5. (Hopefully, Moscow
weather permits it :) )
Also, is it hardware possible to be alarm values type of float, not only
integer?
My OS is:
uname -a
linux linaro-nano 3.0.0-1007-linaro-omap #11~ppa~natty-Ubuntu SMP PREEMPT
Tue Sep 27 20:33:26 UTC 2011 armv7l armv7l armv7l GNU/Linux
Best Regards,
Ivan, PhD
------------------------------------------------------------------------------
This SF email is sponsosred by:
Try Windows Azure free for 90 days Click Here
http://p.sf.net/sfu/sfd2d-msazure
_______________________________________________
Owfs-developers mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/owfs-developers