Am 28.04.2014 13:50, schrieb Johan Ström:
> 
> Mostly this has been working good, with reliable triggering of the
> latch. However, one problem with pull-up based circuit is that I get
> erroneous triggers if VCC disappears, for example due to a bus
> disconnect,
>
> So.. my questions would be:
> a) what does your DS2406/08-setup look like, and have you had any
> similar problems?
>
With a DS2408, I would always check the POR flag and sort out errorneous
latch states in the software.

With a DS2406, there isn't such a POR flag, but you can check the status
byte 7 whether it is in factory setting. That would mean POR. This only
works when you don't use the correspoding setting "Respond to
conditional search when PIO A or B is high".

Kind regards

        Jan

------------------------------------------------------------------------------