hello lars, Lars Marowsky-Bree wrote: >> i have a cluster consisting of two servers: wc01 and wc02. >> no stonith is enabled. >> >> i started wc02. wc02 is plugged into the switch >> i started wc01 - no connection to wc02. >> >> after the servers (and heartbeat) is started, i plug wc01 into the >> switch. the two node find eachother but remain in split-brain mode. > > That's a heartbeat-level issue. Please post to linux-ha and/or file a > bugzilla with hb_report.
ok, i did so. but why exactly do you think its a heartbeat-level issue? from the ccm entries in the logfile? > ... > ccm[2478]: 2008/04/17_14:13:43 info: Break tie for 2 nodes cluster > crmd[2483]: 2008/04/17_14:13:43 info: mem_handle_event: Got an event > OC_EV_MS_INVALID from ccm > ... cheers, raoul -- ____________________________________________________________________ DI (FH) Raoul Bhatia M.Sc. email. [EMAIL PROTECTED] Technischer Leiter IPAX - Aloy Bhatia Hava OEG web. http://www.ipax.at Barawitzkagasse 10/2/2/11 email. [EMAIL PROTECTED] 1190 Wien tel. +43 1 3670030 FN 277995t HG Wien fax. +43 1 3670030 15 ____________________________________________________________________ _______________________________________________ Pacemaker mailing list [email protected] http://list.clusterlabs.org/mailman/listinfo/pacemaker