Max Williams wrote:
Hi,
I have a pair of clustered DNS servers with a virtual IP (VIP) configured. The 
problem is that when the VIP fails over, named on the new host of the VIP will 
not listen on port 53/UDP of the VIP until it is reloaded (I think this is 
because this daemon uses UDP, not TCP).

So I'd like to be able to reload named after a failover of the VIP address. Is 
this possible?

I could do it by configuring named as a cloned resource and then configuring an 
order so that it is restarted when the VIP fails over or moves but I would much 
rather have named reload instead of restart.

Any ideas? I'd rather not have to resort to a wrapper script or anything like 
that.

This seems to be a design decision on the part of the bind authors. There is a parameter

options { interface-interval 1; };

that can be set (in minutes, lowest is 1 minute because 0 disables it) to have bind rescan for new interfaces on the machine.



_______________________________________________
Pacemaker mailing list: Pacemaker@oss.clusterlabs.org
http://oss.clusterlabs.org/mailman/listinfo/pacemaker

Project Home: http://www.clusterlabs.org
Getting started: http://www.clusterlabs.org/doc/Cluster_from_Scratch.pdf
Bugs: http://developerbugs.linux-foundation.org/enter_bug.cgi?product=Pacemaker

Reply via email to