Hello, pacemaker users and developers.

First, many thanks to clusterlabs.org for their software, Pacemaker helps us 
very much!

I am testing cluster configuration based on Pacemaker+CMAN. I configured 
fencing as described in  Pacemker documentation about CMAN based clusters and 
it works.
May be I misunderstood something, but I can't  acknowledge nodes fencing 
manually.
I use fence_ipmilan as device and when I plug out power cable from server 
stonith  fails. I expected this,  of course, but I don't know how to 
acknowledge manual fencing.
When I try stonith_admin -C node_name, it does nothing. 
I see this in logs:

May 17 11:46:52 NODE1 stonith-ng[5434]:   notice: stonith_manual_ack: Injecting 
manual confirmation that NODE2 is safely off/down
May 17 11:46:52 NODE1 stonith-ng[5434]:   notice: log_operation: Operation 
'off' [0] (call 2 from stonith_admin.10959) for host 'NODE2' with device 
'manual_ack' returned: 0 (OK)
May 17 11:46:52 NODE1 stonith-ng[5434]:    error: crm_abort: do_local_reply: 
Triggered assert at main.c:241 : client_obj->request_id                         
                                 
May 17 11:46:52 NODE1 stonith-ng[5434]:    error: crm_abort: crm_ipcs_sendv: 
Triggered assert at ipc.c:575 : header->qb.id != 0                              
                                 
May 17 11:47:35 NODE1 stonith_admin[11162]:   notice: crm_log_args: Invoked: 
stonith_admin -C NODE2                                                          
                    
May 17 11:47:35 NODE1 stonith-ng[5434]:   notice: merge_duplicates: Merging 
stonith action off for node NODE2 originating from client 
stonith_admin.11162.b42172b1 with identical request from 
stonith_admin.10959@NODE1.f2048550 (0s)                                         
                                                                                
                                                                                
    
May 17 11:47:35 NODE1 stonith-ng[5434]:   notice: stonith_manual_ack: Injecting 
manual confirmation that NODE2 is safely off/down                               
                                                   
May 17 11:47:35 NODE1 stonith-ng[5434]:   notice: log_operation: Operation 
'off' [0] (call 2 from stonith_admin.11162) for host 'NODE2' with device 
'manual_ack' returned: 0 (OK)                                  
May 17 11:47:35 NODE1 stonith-ng[5434]:    error: crm_abort: do_local_reply: 
Triggered assert at main.c:241 : client_obj->request_id                         
                                                                   
May 17 11:47:35 NODE1 stonith-ng[5434]:    error: crm_abort: crm_ipcs_sendv: 
Triggered assert at ipc.c:575 : header->qb.id != 0    

Nothing happened after stonith_admin -C.
Fenced still trying to fence_pcmk, and I see lots of "Timer expired" from 
stonith-ng, and failed fence_ipmilan operations.

Yes,  I can do fence_ack_manual on cman-master node, and then cleanup node 
state with cibadmin, but it is very sloooow way. 
If I lost many servers in cluster, for example, lost power in one rack with two 
or more servers, I need a way to running again services on remaining nodes as 
quickly as possible.

I think fencing manual acknowledgement must be fast and simple and I suppose 
that stonith_admin --confirm have to do that.



_______________________________________________