Whenever we connect a host, packetfence is trigggering the system scan violation
and presenting a Scan page for the user and initiates the nessus (external
server) scan, when the user hits the scan button. 

The client is failing on nessus ID:11153, and we modified the violations.conf so
that client will be placed in the islation VLAN if it triggers that nessus ID.

Below is the config

[1100001]
desc=Nessus Scan
url=/remediation.php?template=failed_scan
max_enable=4
button_text=Scan my computer again
trigger=Nessus::11153
actions=email,log,trap
# for faster remediation, it is recommended to leave an offending client in the
registration vl$
vlan=registrationVlan


But even though the client is failing on nessus id-11153 its moving the client
to Normal VLAN instead of leaving it in reg VLAN . We believe that this is not
working as its supposed to be since its a external nessus server. We suspect
that pf server was not able to pull the report from the external nessus server
after the scan. Do we have to do anything special in this case. 

Thanks for your help....


------------------------------------------------------------------------------