On 2010-02-19 20:38, Alexandre Castonguay wrote: > Hi all, > > I can't figure out why the message 'clear' in this patch is not sent to > [oneshot]. Clicking it manually works fine. >
which version on [oneshot] are you using? the abstraction implementation seems to work as expected. the external version, seems to have a re-entrant bug, which explains your problem (the "once" flag is set after the data is sent to the outlet; so when you send "42" to the object, will will immediately send out it's value, triggering the clear message which will force the once-flag to be cleared; then control is returned to [oneshot] which set's the flag, effectively undoing the "clear") this is all markEx trunk. fgmasdr IOhannes