Fred/Brad, Firstly I hope this works ok, I've not posted a message till now but have been reading with great interest!
Though I'm relatively new to 99SE and a bit of a novice I also noticed this problem, my solution was the same as Brad suggests. It's not really a solution as such, more of a work-around, but I decided this was going to be much quicker than finding the root cause of why they did not update correctly! I've been chasing silly things like this more often than not in the year I've been using Protel on and off, you guys seem to know your stuff! I only graduated 2 years ago, I feel a bit out of my depth in the present company on this discussion list! Best Regards Norman Webster Development Engineer Gas Detection Systems -------------------------------------------------------------- Draeger Safety UK Limited www.draeger-safety.com --------------------------------------------------------------- Draeger Safety >> Pioneering Solutions "Brad Velander" <[EMAIL PROTECTED]> Sent by: [EMAIL PROTECTED] 24/05/2005 22:55 Please respond to Protel EDA Discussion List <[email protected]> To "Protel EDA Discussion List" <[email protected]> cc Subject RE:[PEDA] Protel99SE Default designator text height Fred, Yes, that and other similar issues are a bit of a pain in P99SE. However fixing the issue is less than 10 seconds work after they are all added, simply use global change to change all the 60mil Ref. Des. heights to 50mil. Leave it until you have entered all or a significant number of parts, even wait until the final steps of the design and then change their height and locate them. You will notice similar problems with Via tenting. Again it only takes seconds to fix once you have a number of vias in the design. Sincerely, Brad Velander Senior PCB Designer Northern Airborne Technology 1925 Kirschner Rd., Kelowna, BC, V1Y 4N7. tel (250) 763-2329 ext. 225 fax (250) 762-3374 -----Original Message----- From: Fred Bloggs [mailto:[EMAIL PROTECTED] Sent: May 24, 2005 2:15 AM To: [email protected] Subject: [SPAM] - [PEDA] Protel99SE Default designator text height - Email found in subject When I update the PCB from schematic the designator text height is set to 60mils. I have changed the default in preferences so it's 50 and indeed if I manually place a component the designator text height is 50mils. However when I update the PCB from schematic, a new component has a designator text height of 60mils. Where am I going wrong? Yours very frustrated! Fred ____________________________________________________________ You are subscribed to the PEDA discussion forum To Post messages: mailto:[email protected] Unsubscribe and Other Options: http://techservinc.com/mailman/listinfo/peda_techservinc.com Browse or Search Old Archives (2001-2004): http://www.mail-archive.com/[email protected] Browse or Search Current Archives (2004-Current): http://www.mail-archive.com/[email protected] ____________________________________________________________ You are subscribed to the PEDA discussion forum To Post messages: mailto:[email protected] Unsubscribe and Other Options: http://techservinc.com/mailman/listinfo/peda_techservinc.com Browse or Search Old Archives (2001-2004): http://www.mail-archive.com/[email protected] Browse or Search Current Archives (2004-Current): http://www.mail-archive.com/[email protected]