Muhammad Nazir wrote:
Hi
I am new to using Protel. I captured my design in a schematic and then
updated my PCB file. I got the following errors:

1- Violation between SMT Small Component R14(4840mil,4540mil) on Top Layer and
                     Room Amp-CFD5 (Bounding Region = (7475mil,
3180mil, 22145mil, 3770mil)

I usually delete the rooms - they are apparently useful on multi-channel designs, but may cause problems on simpler jobs.

The above error appears as soon as a components is  dragged onto the
PCB board for placement from the block on the side of the board
outline. It seems that the software takes this block as the 'room'
rather than making the board outine its 'room'.

2- I have an IC which is a QFN package with 32 Terminals, Body 5 x 5
mm and Pitch 0.5 mm. Four pads of this IC have a short circuit with
their own selves as shown by the following error.
Short-Circuit Constraint (Allowed=No) (All),(All)
   Violation between Pad CMP1-12(4425.158mil,4215.984mil)  Top Layer and
                     Pad CMP1-12(4425.158mil,4223.465mil)  Top Layer

Looks like your footprint has two pads called "12" at the same position. Go to the PCB library editor and delete the extra pad.

3- I want to place components on both sides of the board but the
software does NOT let me  place the components on the bottom layer
although I can see it (as a single layer as well as a multi-layer). I
did tell the software that I would put comonents on both sides when I
used the wizard to create the board. Could anyone let me know what am
I missing here?

I think you hit "*" on the numeric keypad while placing a part to flip it to the other side. Otherwise, hit "tab" while placing the part - there is a layer selection on that form.

I appreciate your help in advance.

Thanks

____________________________________________________________
You are subscribed to the PEDA discussion forum

To Post messages:
mailto:[email protected]

Unsubscribe and Other Options:
http://techservinc.com/mailman/listinfo/peda_techservinc.com

Browse or Search Old Archives (2001-2004):
http://www.mail-archive.com/[email protected]
Browse or Search Current Archives (2004-Current):
http://www.mail-archive.com/[email protected]



--
Peter Bennett
TRIUMF
4004 Wesbrook Mall, Vancouver, BC, Canada
GPS and NMEA info and programs:
http://vancouver-webpages.com/peter/index.html




____________________________________________________________
You are subscribed to the PEDA discussion forum

To Post messages:
mailto:[email protected]

Unsubscribe and Other Options:
http://techservinc.com/mailman/listinfo/peda_techservinc.com

Browse or Search Old Archives (2001-2004):
http://www.mail-archive.com/[email protected]

Browse or Search Current Archives (2004-Current):
http://www.mail-archive.com/[email protected]

Reply via email to