Brad,
        I don't use the autorouter so I am no expert but you probably have DRC 
rules that are telling it the tracks should be a different width track (look at 
your track width rules for various nets). Additionally, you will want to "lock" 
existing pre-routes. How precisely you do that I am not sure, I am also not 
sure if that locking pre-routes works properly in 99SE.

Sincerely,
Brad Velander
Senior PCB Designer
Northern Airborne Technology
1925 Kirschner Rd.,
Kelowna, BC, V1Y 4N7.
tel (250) 763-2329 ext. 225
fax (250) 762-3374


-----Original Message-----
From: Brad Kosiance [mailto:[EMAIL PROTECTED]
Sent: August 2, 2005 4:03 PM
To: [email protected]
Subject: [PEDA] Auto Router.


I have manually placed all the components on the PCB and manually placed all
the power tracks to a certain track width grater than the minimum specified
in the design rules.

When I use the Auto router it resizes the tracks I already placed.

Can this be disabled?

 

 

Protel99SE.

 

Thanks,

Brad.