On Sun, Oct 14, 2012 at 11:26:40AM +0800, Craig Ringer wrote:
> On 10/14/2012 11:00 AM, John R Pierce wrote:
> >On 10/13/12 7:13 PM, Craig Ringer wrote:
> >>
> >>* Use a good quality hardware RAID controller with a battery backup
> >>cache unit if you're using spinning disks in RAID. This is as much for
> >>performance as reliability; a BBU will make an immense difference to
> >>database performance.
> >
> >a comment on this one....   I have some test servers with lots of SAS
> >and/or SATA drives on controllers like LSI Logic 9261-8i, with 512MB or
> >1GB battery-backed cache.     I can configure the controller for JBOD
> >and use linux mdraid raid10 and get the same performance as the
> >controllers native raid10, as long as the write-back cache is
> >enabled.     disable the writeback cache, and you might as well be using
> >SATA JBOD.
> 
> Yeah, without the write-back cache you don't gain much. I run a
> couple of DBs on plain old `md` RAID and I'm actually quite happy
> with it.
> 
> I've expanded this into a blog post and improved that section there.
> 
> http://blog.ringerc.id.au/2012/10/avoiding-postgresql-database-corruption.html

Craig, that is a great post.  Can you get it on Planet Postgres?

        http://planet.postgresql.org/

I think you would have to subscribe your RSS blog feed.

-- 
  Bruce Momjian  <br...@momjian.us>        http://momjian.us
  EnterpriseDB                             http://enterprisedb.com

  + It's impossible for everything to be true. +


-- 
Sent via pgsql-general mailing list (pgsql-general@postgresql.org)
To make changes to your subscription:
http://www.postgresql.org/mailpref/pgsql-general

Reply via email to