Sridhar N Bamandlapally wrote:
> the actual issue is, when
> 
> 1. temp table <say tmp1>is created with rows
> 2. stats/analyze on table (tmp1)
> 3. table dropped (tmp1)
> 
> but in stats related catalog tables a blot is created

What is a blot in this context? Are you talking about "bloat"?

> In this scenario, thousands of temp tables created per day, blots are 
> increasing and stats related
> tables are growing to 10's of GB
> 
> however, we schedule vacuum on catalog tables to control size
> 
> the worry is, catalog tables also undergo MVCC concept
> 
> I think when table is dropped, should have option to remove or reuse related 
> blot-space on catalog
> tables

It must be "bloat" you're talking about.

Do you have "autovacuum = on"?
If yes, it should take care of the problem if there are only thousands
of temporary tables per day.

What do you get for
   SELECT last_autovacuum, last_autoanalyze
   FROM pg_stat_sys_tables
   WHERE schemaname = 'pg_catalog' AND relname = 'pg_statistic';

Yours,
Laurenz Albe

-- 
Sent via pgsql-general mailing list (pgsql-general@postgresql.org)
To make changes to your subscription:
http://www.postgresql.org/mailpref/pgsql-general

Reply via email to