On 24.11.21 07:11, Masahiko Sawada wrote:
I haven’t looked at the patch deeply but regarding 007_sync_rep.pl,
the tests seem to fail since the tests rely on the order of the wal
sender array on the shared memory. Since a background worker for
synchronizing replication slots periodically connects to the walsender
on the primary and disconnects, it breaks the assumption of the order.
Regarding 010_logical_decoding_timelines.pl, I guess that the patch
breaks the test because the background worker for synchronizing slots
on the replica periodically advances the replica's slot. I think we
need to have a way to disable the slot synchronization or to specify
the slot name to sync with the primary. I'm not sure we already
discussed this topic but I think we need it at least for testing
purposes.

This has been addressed by patch v2 that adds such a setting.



Reply via email to