On Mon, Sep 1, 2025 at 5:07 PM Zhijie Hou (Fujitsu)
<[email protected]> wrote:
>
>
> I reviewed the patch internally and tweaked a small detail of the apply worker
> to reduce the waiting time in the main loop when max_retention_duration is
> defined (set wait_time = min(wait_time, max_retention_duration)). Also, I 
> added
> a simple test in 035_conflicts.pl of 0001 to verify the new sub option.
>
> Here is V70 patch set.
>

The patch v70-0001 looks good to me. Verified, all the old issues are resolved.

Will resume review of v70-0002 now.

thanks
Shveta