On Sun, Aug 26, 2018 at 06:00:23PM +0200, Alexander Kukushkin wrote: > it is possible to start bgworker with bgw_start_time = > BgWorkerStart_PostmasterStart, which will be started immediately after > postmaster.
Right. > But if you try to do a fast shutdown while postmaster still in the > pmState == PM_STARTUP, bgworker will never get SIGTERM and postmaster > will wait forever. > At the same time, if you do immediate or smart shutdown, it works fine. > > The problem is in the pmdie function. Proposed fix attached. That seems like a good catch and a correct fix to me. The handling of SIGINT is inconsistent with SIGTERM in pmdie(). I would just add a comment to mention that at this stage only the startup process is running, and that it has been signaled already. I'll commit that tomorrow. -- Michael
signature.asc