Hi Shveta,

On Fri, May 15, 2026 at 9:28 AM shveta malik <[email protected]> wrote:
>
> Ashutosh, while testing further, I noticed that
> 'synchronized_standby_slots' does not filter duplicate entries. As an
> example, if user ends up giving one entry twice in priority
> configuration, then we will end up waiting on one slot twice rather
> than waiting on 2 different slots.
>

Thank you for raising this concern. It is indeed an issue that needs
fixing. We will ensure it is addressed in the next patch version.

--
With Regards,
Ashutosh Sharma.