"scott.marlowe" <[EMAIL PROTECTED]> writes:
> Is setting the max connections to something like 200 reasonable, or likely 
> to cause too many problems?

That would likely run into number-of-semaphores limitations (SEMMNI,
SEMMNS).  We do not seem to have as good documentation about changing
that as we do about changing the SHMMAX setting, so I'm not sure I want
to buy into the "it's okay to expect people to fix this before they can
start Postgres the first time" argument here.

Also, max-connections doesn't silently skew your testing: if you need
to raise it, you *will* know it.

                        regards, tom lane

---------------------------(end of broadcast)---------------------------
TIP 6: Have you searched our list archives?

http://archives.postgresql.org

Reply via email to