I wrote: > I found that the autovacuum launcher continues to run and spawn workers > after reloading the configuration file with autovacuum = off in CVS HEAD.
Sorry, I found this issue will be fixed in the 'more autovacuum fixes' patch. The workers still continues to run, but it would be not a serious problem. Regards, --- ITAGAKI Takahiro NTT Open Source Software Center ---------------------------(end of broadcast)--------------------------- TIP 6: explain analyze is your friend