[EMAIL PROTECTED] wrote:
you can? I've never seen a raid 5 setup with more then a single parity dirve (or even the option of having more then one drives worth of redundancy). you can have hot-spare drives, but thats a different thing.

With RAID 4, where the "parity drives" are in fact dedicated to parity information, the controller could just store the parity data mirrored on more than one drive. Unfortunately write performance on RAID 4 is absolutely horrible, and a second or third parity disk would not help with that.

I suppose there's nothing stopping a controller adding a second disk's worth of duplicate parity information when striping a four or more disk RAID 5 array, but I thought that's basically what RAID 6 was.

--
Craig Ringer

--
Sent via pgsql-performance mailing list (pgsql-performance@postgresql.org)
To make changes to your subscription:
http://www.postgresql.org/mailpref/pgsql-performance