This is an automatically generated e-mail. To reply, visit:
http://reviewboard.kde.org/r/2485/
-----------------------------------------------------------

Review request for Plasma.


Summary
-------

When a notification with actions is shown, clicking an action button causes the 
ActionInvoked (and NotificationClosed) signals to be emitted twice. See this 
bug report: https://bugs.edge.launchpad.net/ubuntu/+source/banshee/+bug/501677

It seems the QDBusAbstractAdaptor automatically forward signals, even if I find 
no evidence of this in the source code.


Diffs
-----

  
trunk/KDE/kdebase/workspace/plasma/generic/dataengines/notifications/notificationsengine.cpp
 1065171 

Diff: http://reviewboard.kde.org/r/2485/diff


Testing
-------

- Monitor the signals with: dbus-monitor 
"interface=org.freedesktop.Notifications,type=signal"
- Start an application which show a notification with actions. I used the 
test-multi-actions.py example from python-notify.
- Click an action, notice both signals are listed twice.
- After the patch, signals are only listed once.


Thanks,

Aurélien

_______________________________________________
Plasma-devel mailing list
Plasma-devel@kde.org
https://mail.kde.org/mailman/listinfo/plasma-devel

Reply via email to