mart created this revision. mart added a reviewer: Plasma. Restricted Application added a project: Plasma. Restricted Application added a subscriber: plasma-devel.
REVISION SUMMARY restore the missing panel properties: alignment minimum length maximum length offset also, allow non integer values for the measures (height, min/max, offset) BUG:368074 BUG:367918 TEST PLAN dumped a config with a custom panel, different height/alignment/offset etc started a new plasma session with that l&f package, restored panel correctly REPOSITORY rPLASMAWORKSPACE Plasma Workspace BRANCH phab/panelrestore REVISION DETAIL https://phabricator.kde.org/D3021 AFFECTED FILES shell/scripting/scriptengine_v1.cpp shell/shellcorona.cpp EMAIL PREFERENCES https://phabricator.kde.org/settings/panel/emailpreferences/ To: mart, #plasma Cc: plasma-devel, lesliezhai, ali-mohamed, jensreuterberg, abetts, sebas