broulik added a comment.

  I just noticed when I change the setting in the KCM the icon changes to the 
warning icon but the button stays enabled, only if I restart plasma the button 
is disabled

INLINE COMMENTS

> appmenuapplet.h:69
> +    bool appletEnabled() const;
> +    void updateAppletEnabled();
> +

Needs to be a slot:

  public slots:
      void updateAppletEnabled();

that's why your connection doesn't work

> main.qml:120
>  
> +    Plasmoid.toolTipSubText: !appletEnabled ? i18n("Application Menu Widget 
> is disabled in settings.\n\nGo to Settings > Application Style > Fine 
> Tuning(tab) to enable it again.") : ""
> +

Go to System Settings → Application Style → Fine Tuning (tab) to enable it. (I 
would still love if you could add a way for the user to open that KCM, perhaps 
in context menu?)

> main.qml:33
>  
> -    readonly property bool compactView: plasmoid.configuration.compactView
> +    property bool appletEnabled: plasmoid.nativeInterface.appletEnabled
>  

Make it readonly property

> main.qml:122
> +
> +        onMenuAvailable: {
> +            if (appletEnabled) {

Can we make it a binding instead of manually onFooChanged?

REPOSITORY
  R120 Plasma Workspace

REVISION DETAIL
  https://phabricator.kde.org/D4070

EMAIL PREFERENCES
  https://phabricator.kde.org/settings/panel/emailpreferences/

To: chinmoyr, davidedmundson
Cc: broulik, plasma-devel, lesliezhai, ali-mohamed, jensreuterberg, abetts, 
sebas