https://bugs.kde.org/show_bug.cgi?id=350365

Marco Richetta <marcoriche...@gmail.com> changed:

           What    |Removed                     |Added
----------------------------------------------------------------------------
                 CC|                            |marcoriche...@gmail.com

--- Comment #23 from Marco Richetta <marcoriche...@gmail.com> ---
Same problem here with 
- Kubuntu 18.04 
- KDE Frameworks 5.44
- KDE Plasma 5.12.6
- Kernel 4.15.0-34-generic
- UPower is at version 0.99.7.

Reproducible: Almost always

Steps to reproduce:
1. After logon, unplug and plug the battery.
2. Close session and login again.
3. Battery is showed by plasmoid and detected by UPower.

*Sometimes battery is detected before the session is closed.

upower-d output:

BEFORE BEING DETECTED
=====================

Device: /org/freedesktop/UPower/devices/line_power_ADP1
  native-path:          ADP1
  power supply:         yes
  updated:              mar 25 sep 2018 06:56:19 -03 (191 seconds ago)
  has history:          no
  has statistics:       no
  line-power
    warning-level:       none
    online:              no
    icon-name:          'ac-adapter-symbolic'

Device: /org/freedesktop/UPower/devices/DisplayDevice
  power supply:         no
  updated:              mar 25 sep 2018 06:56:19 -03 (191 seconds ago)
  has history:          no
  has statistics:       no
  unknown
    warning-level:       none
    icon-name:          'battery-missing-symbolic'

Daemon:
  daemon-version:  0.99.7
  on-battery:      no
  lid-is-closed:   no
  lid-is-present:  yes
  critical-action: HybridSleep

AFTER BEING DETECTED
====================

Device: /org/freedesktop/UPower/devices/line_power_ADP1
  native-path:          ADP1
  power supply:         yes
  updated:              mar 25 sep 2018 06:56:19 -03 (988 seconds ago)
  has history:          no
  has statistics:       no
  line-power
    warning-level:       none
    online:              no
    icon-name:          'ac-adapter-symbolic'

Device: /org/freedesktop/UPower/devices/battery_BAT1
  native-path:          BAT1
  vendor:               -Real Battery 1-
  model:                CRB Battery 1
  serial:               Battery 1
  power supply:         yes
  updated:              mar 25 sep 2018 07:11:47 -03 (60 seconds ago)
  has history:          yes
  has statistics:       yes
  battery
    present:             yes
    rechargeable:        yes
    state:               charging
    warning-level:       none
    energy:              3,118 Wh
    energy-empty:        0 Wh
    energy-full:         3,325 Wh
    energy-full-design:  4,4 Wh
    energy-rate:         0 W
    percentage:          93%
    capacity:            75,5682%
    icon-name:          'battery-full-charging-symbolic'
  History (charge):
    1537870306  93,000  charging
    1537870306  0,000   unknown
  History (rate):
    1537870306  0,000   unknown

Device: /org/freedesktop/UPower/devices/DisplayDevice
  power supply:         yes
  updated:              mar 25 sep 2018 07:11:46 -03 (61 seconds ago)
  has history:          no
  has statistics:       no
  battery
    present:             yes
    state:               charging
    warning-level:       none
    energy:              3,118 Wh
    energy-full:         3,325 Wh
    energy-rate:         0 W
    percentage:          93%
    icon-name:          'battery-full-charging-symbolic'

If I can reproduce this behaviour it would be useful
to find the logs of this activity, but I don't know where to look.

*On x.sessionerrors it's shown only one "Unable to assign [undefined] to int"