> Wiadomość napisana przez lord_Niedzwiedz <sir_mis...@o2.pl> w dniu 27 lis > 2015, o godz. 12:11: > > Nie bardzo znam się na smarcie ;-/ > Co dziennie z serwera dostaję taki komunikat: > > "This message was generated by the smartd daemon running on: > > host name: louve > DNS domain: XXX.net > > The following warning/error was logged by the smartd daemon: > > Device: /dev/sdd [SAT], 3 Currently unreadable (pending) sectors > > Device info: > WDC WD30EZRX-00MMMB0, S/N:WD-WCAWZ1499279, WWN:5-0014ee-25b9c49c1, > FW:80.00A80, 3.00 TB > > For details see host's SYSLOG:" > > Daję: > smartctl -t long /dev/sdd > smartctl -a /dev/sdd
I dobrze, nawet odpaliłeś ten test - bo: > > 9 Power_On_Hours 0x0032 052 052 000 Old_age Always - > 35409 > SMART Self-test log structure revision number 1 > Num Test_Description Status Remaining LifeTime(hours) > LBA_of_first_error > # 1 Extended offline Completed: read failure 90% 35408 > 1655189241 > # 2 Extended offline Completed: read failure 90% 29310 > 101097888 czyli najświeższy test odpaliłeś godzinę temu (35408) i się wywalił na odczycie. Gorzej że już od połowy marca jest źle, bo wtedy robiłeś pierwszy test który się identycznie wyłożył… Pozdrawiam, -- Jacek Osiecki josie...@silvercube.pl Silvercube s.c. ul. Makuszynskiego 4 31-752 Kraków +48 (12) 684 21 00 _______________________________________________ pld-users-pl mailing list pld-users-pl@lists.pld-linux.org http://lists.pld-linux.org/mailman/listinfo/pld-users-pl