Hi Bernd, You appear to be using VLANs - please try amending your 'aggregate_filter' lines in the following fashion: 'vlan and <existing statement>'. Let me know whether that solves the issue.
Cheers, Paolo On Wed, Jun 08, 2011 at 10:26:57AM +0000, Bernd Bornkessel wrote: > Hi, > > we want to you sfacctd for accounting and billing purposes in our network. I > set up a test installation with a router sending SFlow and a Debian 6.0 > system with pmacct-0.14.0rc1 and a mysql backend as the collector. > > Everything works fine as long as I don't use the aggregate filters. Without > aggregate filtering sfacctd will write the data to the database. > But as we need to have filters for our own networks, I tried to use the > aggregate filters. But as soon as I activate them, there will be no data > written to the database. > > The problem exists with all backends (mysql, memory, sqlite etc.). Thus I > assume the filters not matching. But according to the sent flows and the > configured filters, there should be flow data afer filtering. > > [ ... ] _______________________________________________ pmacct-discussion mailing list http://www.pmacct.net/#mailinglists