Hi Andrew,

You should be looking for the nfacctd_renormalize/sfacctd_renormalize
feature. Define it and set it to true in your configuration file, ie.

sfacctd_renormalize: true

Cheers,
Paolo

On Mon, Apr 23, 2012 at 01:34:56PM +0100, Andrew Hearn wrote:
> Hello,
> 
> Really sorry to ask this, I'm using sfacctd and the mysql plug-in - it
> doesn't look like the data is being sampled up when saving to the
> database - I don't see an configuration options  regarding the sample rate.
> 
> I'm currently using 1 in 1,000 on our switches, I assume that the sample
> rate needs to be applied when processing the data from the database, and
> it's not applied when sfacctd writes the date to the database?
> 
> Thanks!


_______________________________________________
pmacct-discussion mailing list
http://www.pmacct.net/#mailinglists

Reply via email to