Have you tried with "nfacctd_renormalize: true"?

http://wiki.pmacct.net/OfficialConfigKeys

BT


On Thu, Nov 15, 2012 at 1:22 AM, Wei Wang <[email protected]> wrote:

> Hi all,
>
>        I am doing a system which is used to monitor the internet usage of
> customer for administrator.
>
>        I use netflow to capture data, and nfacctd to analyse the netflow
> packages
>
>        Everything is set up, and it works fine, but when I am doing the
> accuracy  test, it seems that the amount of data which nfacctd stored in
> mysql does not match the amount of data I
>
>        used.
>
>
>        Here is my config file:
>
>         daemonize: true
>
> debug: true
>
> nfacctd_time_new: true
>
> nfacctd_ip: X.X.X.X
>
> nfacctd_port: 9990
>
> !logfile: /netflow/pmacct/logfile/file.log
>
>
>
> plugin_pipe_size: 20480000
>
> plugin_buffer_size: 20480
>
>
>
> aggregate[inbound]: dst_host
>
> !aggregate[outbound]: src_host
>
>
>
> aggregate_filter[inbound]: dst net X.X.69.0/24
>
> !aggregate_filter[outbound]: src net X.X.69.0/24
>
>
>
> plugins: mysql[inbound]
>
>
>
> sql_table[inbound]: acct_in_%Y_%m
>
> !sql_table[outbound]: acct_out_%M
>
>
>
>
>
> sql_host: localhost
>
> sql_user: XXXXX
>
> sql_passwd: XXXXX
>
> sql_db: pmacct
>
> sql_refresh_time: 300
>
> sql_history: 1h
>
> sql_history_roundoff: m
>
> sql_table_schema[inbound]: /netflow/app.schema
>
> !sql_table_schema[outbound]: /netflow/app1.schema
> sql_optimize_clauses: true
>
>
> Here is the database rows
>
>      ip_dst                  packs           bytes      time-inserted
>                    time-updated
> '', 'X.X.69.105', '',   32,               8662, '2012-11-15 18:30:00',
> '2012-11-15 18:40:02'
> '', 'X.X.69.105', '',   127,            36625, '2012-11-15 12:00:00',
> '2012-11-15 13:00:02'
> '', 'X.X.69.105', '',  122,             35258, '2012-11-15 13:00:00',
> '2012-11-15 14:00:01'
> '', 'X.X.69.105', '',  134,             38194, '2012-11-15 14:00:00',
> '2012-11-15 15:00:01'
> '', 'X.X.69.105', '',  122,             35134, '2012-11-15 15:00:00',
> '2012-11-15 16:00:02'
> '', 'X.X.69.105', '',  131,             38963, '2012-11-15 16:00:00',
> '2012-11-15 17:00:01'
> '', 'X.X.69.105', '',  85,               24814, '2012-11-15 17:00:00',
> '2012-11-15 17:45:02'
> '', 'X.X.69.105', '',  8,                 2288, '2012-11-15 17:40:00',
> '2012-11-15 17:50:02'
> '', 'X.X.69.105', '',  104,            29849, '2012-11-15 17:50:00',
> '2012-11-15 18:00:03'
> '', 'X.X.69.105', '',  104,             24938, '2012-11-15 18:00:00',
> '2012-11-15 18:10:02'
> '', 'X.X.69.105', '',  348,             97539, '2012-11-15 18:10:00',
> '2012-11-15 18:20:03'
> '', 'X.X.69.105', '',  58,               14317, '2012-11-15 18:20:00',
> '2012-11-15 18:30:01'
> '', 'X.X.69.105', '',  32,               8662, '2012-11-15 18:30:00',
> '2012-11-15 18:40:02'
>
> Actually I was downloading a big file during this time.
>
> I cannot figure this out, and also network is pretty new for me. Any helps
> will be appreciate!
>
>
>
>
> _______________________________________________
> pmacct-discussion mailing list
> http://www.pmacct.net/#mailinglists
>



-- 
Brian Talley
[email protected]
_______________________________________________
pmacct-discussion mailing list
http://www.pmacct.net/#mailinglists

Reply via email to