Greetings All,
I am in need of some SAM's, ISOCs units, Exploranium's and IPM-7/8 or similar portal monitors. Please call or email if you have any excess. Thanks, Rob Robert J. Gunter, MSc, CHP CHP Consultants/CHP Dosimetry www.chpconsultants.com www.chpdosimetry.com Toll Free: (888) 766-4833 Fax: (866) 491-9913 Cel: (865) 387-0028 [email protected] From: [email protected] [mailto:[email protected]] On Behalf Of BJ Thompson Sent: Saturday, September 18, 2010 11:12 AM To: [email protected] Subject: RE: Powernet: TLD and ED worn in close proximity North Anna does not use such a device. Workers are trained to maintain these in close proximity of each other. We have procedural guidance to keep them in close proximity, defined as within a hand width. We perform periodic observations in the field and question workers if a dose correlation occurs. Barbara J. Thompson Supervisor of Exposure Control Dominion - North Anna Power Station Email: [email protected] Phone: 540-894-2605 Beeper: #3469 FAX: 540-894-2408 From: [email protected] [mailto:[email protected]] On Behalf Of Egert, Glenn W. Sent: Monday, September 13, 2010 6:35 PM To: [email protected] Cc: Shepherd, R Mark Subject: Powernet: TLD and ED worn in close proximity Columbia requests the following information. 1) Do you use a device such as a geometry card or bag to ensure the TLD and electronic dosimeter (ED) are worn in close proximity on the worker? 2) On what types of jobs do you require the use of this device, e.g., only contaminated areas where PCs (or lab coats) are worn, work involving dose gradients, every time an ED is worn, etc.? Thank you in advance. Glenn W. Egert Radiological Support, Dosimetry Columbia Generating Station Energy Northwest (509) 377-4418 [email protected] CONFIDENTIALITY NOTICE: This electronic message contains information which may be legally confidential and or privileged and does not in any case represent a firm ENERGY COMMODITY bid or offer relating thereto which binds the sender without an additional express written confirmation to that effect. The information is intended solely for the individual or entity named above and access by anyone else is unauthorized. If you are not the intended recipient, any disclosure, copying, distribution, or use of the contents of this information is prohibited and may be unlawful. If you have received this electronic transmission in error, please reply immediately to the sender that you have received the message in error, and delete it. Thank you.
