HNP

Michael Seabock
Lead Radiation Control Specialist - ALARA
Harris Nuclear Plant
T- 919.362.2808
P- 919.982.5466
[email protected]


From: [email protected] [mailto:[email protected]] On Behalf Of 
Thomson, Raymond W.
Sent: Tuesday, November 16, 2010 1:34 PM
To: [email protected]
Subject: Powernet: Challenging A Workers Ability To Hear Dosimeter Alarms

Columbia Generating Station is requesting the following information:

1)    Does your facility challenge a workers ability to hear Direct Reading 
Dosimeter alarms? Yes

2)    How and when is this testing conducted? During TLD issuance, alarm 
sounded out of worker sight

3)    Do you challenge a workers ability to hear Direct Reading Dosimeter 
alarms in a high noise background area when using an enhanced alarming 
dosimeter such as a PAM 1 or PAM-TRX? Use the new I-PAMs

4)    Do you test outage workers during Radiation Worker initial training? No

5)    What measures do take if a worker fails the hearing challenge test? Gets 
flagged in access control with a restriction displayed every log-in as a 
reminder


Thanks In Advance,

Ray Thomson
Health Physics Staff Advisor
Columbia Generating Station
[email protected]
Office, 509-377-8273
Pager, 509-780-0339