V. C. Summer provides the following response: (see below)
Greg Gowdy, PhD, CHP Sr. Staff Health Physicist V. C. Summer Nuclear Station Jenkinsville, SC 29065 (803)-345-4426 (work) (803)-873-1561 (cell) [cid:[email protected]] From: [email protected] [mailto:[email protected]] On Behalf Of Kelton, Gwenna Sent: Friday, April 08, 2011 2:16 PM To: '[email protected]' Subject: Powernet: Dosimetry Questions Please provide answers to the following questions: 1. Do you perform a baseline whole body count when you issue dosimetry? Yes 2. Do you perform an exit whole body count when dosimetry is returned? Yes 3. Which whole body counters do you use? Nuclear Data People Mover Stand-Up Counter (NaI(Tl)) and Chair Counter with 2 HPGe (for Lung and Lower Torso and NaI(Tl) for Thyroid 4. Do you use intercomparison testing for the whole body counting systems? Yes, do intercomparison testing with a vendor at least once/year per WBC although many years we do the IC twice/year Gwenna Asher-Kelton Sr. Radiation Protection Technician Dosimetry Technician STPNOC 361-972-4323 [email protected]
<<inline: image001.jpg>>